追溯生活 笑~笑

生活随笔 技术点滴

RSS Feed

VMware Workstation 8 RAC 共享磁盘配置

0 Comments
Posted by 笑笑 on 2011年12月15日 at 9:39 上午

vmware server配置已经不存在问题了,

winddows 7对vmware server1.0.8的支持不太好,决定采用VMware Workstation 8试试,官方说支持share disk了下面是配置方式

首先在任意一节点增加四块磁盘分别:两个1GB(OCR),一个6GB(数据盘),一个5GB(日志盘)

添加磁盘的时候选择:

Independent-Persistent

Allocate all disk space now – store virtual disk as a single file

添加完以后记得更改下所有磁盘的SCSI总线,选中磁盘,然后点击右边的Advanced

 弹出的Virtual device node中选择1:0

 其他几个共享盘依次操作,分别是1:1,1:2,1:3

配置磁盘共享参数

 

找到两个节点的RHEL5 11GR2 RAC1.vmx ,RHEL5 11GR2 RAC1.vmx 文件

 

将其中文件末尾的scsi1相关的内容改为如下格式

 

scsi1.present = “TRUE”

scsi1.virtualDev = “lsilogic”

scsi1.sharedBus = “virtual”

scsi1:0.present = “TRUE”

scsi1:0.fileName = “E:\VMware\RAC\share\OCR1.vmdk”

scsi1:0.mode = “independent-persistent”

scsi1:0.deviceType = “disk”

scsi1:1.present = “TRUE”

scsi1:1.fileName = “E:\VMware\RAC\share\OCR2.vmdk”

scsi1:1.mode = “independent-persistent”

scsi1:1.deviceType = “disk”

scsi1:2.present = “TRUE”

scsi1:2.fileName = “E:\VMware\RAC\share\DATA.vmdk”

scsi1:2.mode = “independent-persistent”

scsi1:2.deviceType = “disk”

scsi1:3.present = “TRUE”

scsi1:3.fileName = “E:\VMware\RAC\share\BACK.vmdk”

scsi1:3.mode = “independent-persistent”

scsi1:3.deviceType = “disk”

disk.locking = “FALSE”

diskLib.dataCacheMaxSize = “0″

diskLib.dataCacheMaxReadAheadSize = “0″

diskLib.dataCacheMinReadAheadSize = “0″

diskLib.dataCachePageSize = “4096″

diskLib.maxUnsyncedWrites = “0″

修改完成后启动两个节点,在两个节点分别执行fdisk -l是都可以刚增加的四块硬盘的

安装rac的时候会遇到一个错误,bug,忽略即可,生产环境且不可忽略。

Checking shared storage accessibility…

 

WARNING:

rac1:Unable to determine the sharedness of /dev/sda on nodes:

rac2,rac1

 

WARNING:

rac1:Unable to determine the sharedness of /dev/sdb on nodes:

rac2,rac1

 

WARNING:

rac1:Unable to determine the sharedness of /dev/sdc on nodes:

rac2,rac1

 

WARNING:

rac1:Unable to determine the sharedness of /dev/sdd on nodes:

rac2,rac1

 

WARNING:

rac1:Unable to determine the sharedness of /dev/sde on nodes:

rac2,rac1

No shared storage found

Shared storage check failed on nodes “rac2,rac1″

Filed under DataBase
You can leave a comment, or trackback from your own site.

0 Comments

You can be the first to comment!

发表评论

电子邮件地址不会被公开。

您可以使用这些 HTML 标签和属性: <a href="" title=""> <abbr title=""> <acronym title=""> <b> <blockquote cite=""> <cite> <code> <del datetime=""> <em> <i> <q cite=""> <strike> <strong>